• E+H 73F Vortex Flowmeter
Description
Specification
Fluid temperature range 200 ... +400°C
The pressure level PN 40/Class 300 (models with high pressure levels can be ordered as needed)
Sensor comes with reducer (Type R = Level 1, Type S = Level 2)
Optional dual-sensor flow meter (Dualsens type) for redundant measurement with two sensors and two sets of electronic modules
·DN15-DN300
Vortex flow measurement system
Reliable flow measurement of gases, vapors and liquids
Prowirl series sensors have gone through 100,000 trials and tests and have the following advantages · Not affected by the following factors:
- Vibration (more than 1 g in all directions)
- Temperature shock (> 150 K/s)
- Contamination of fluid media
- Water hammer impact
· Maintenance-free, no moving parts, no zero drift ("life cycle" calibration)
· Software initialization settings, saving time and operating costs
Prowirl provides the following extensions  A single instrument can complete the mass measurement of saturated steam or liquid
· Built-in flow computer that calculates mass flow based on volumetric flow measurements and temperature measurements
· External pressure input for superheated steam and gas measurement (optional)
· External temperature input for heat exchange measurement (optional)
Universal volume flow measurement of gases, vapors and liquids.
With built-in temperature measurement, as well as reading external pressure measurements, it is possible to calculate steam, water (according to IAPWS-IF97 ASME standard), natural gas (according to AGA NX-19/AGA8-DC92 detailed method/AGA8 Gross Method 1/SGERG-88
Application scope · Fluid temperature range -200 ... +400 °C
· The pressure level can reach PN 40/Class 300 (models with higher pressure levels can be ordered according to needs)
· Sensor comes with reducer (Type R = Level 1, Type S = Level 2)
·Optional dual-sensor flow meter (Dualsens type) for redundant measurement with two sensors and two sets of electronic modules
Explosion-proof certification · ATEX, FM, CSA, TIIS, NEPSI, IEC
Connection interface to process control system:
· HART, PROFIBUS PA, FF Foundation Fieldbus
safety · Pressure Equipment Directive
· SIL 1

Leave a message
FirstName*
LastName*
Email*
Message*